Browse all practice questions for the Data Center Certified Associate (DCCA) Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Data Center Certified Associate (DCCA) Practice Exam course image
How All-Air HVAC Systems Cool Spaces and Remove MoistureWhich HVAC system type uses sensible and latent cooling through cold supply air?In data centers, the parallel redundant UPS setup with N+1 adds one extra module and keeps all units from the same vendor to share a single critical loadWhich topology is also called an N+1 system and requires UPS modules from the same company, with models sharing a critical load?Understanding how heat moves: conduction happens through direct molecular interactionsWhich mechanism of heat transfer occurs through direct molecular interactions and collisions?Understanding radiator cooling systems in generators: how coolant loops and radiators keep engines safeGenerator cooling is described as which of the following?Understanding the control loop: from input to feedback in a data center control systemIn a control system, which description best fits a control loop?What is the unit of frequency and why is it called the hertz?What is the unit of frequency measurement?What is voltage fluctuation and how it affects data center power qualityWhich term describes a systematic variation of the voltage waveform or small random voltage changes?What makes an isolation transformer unique: galvanic isolation plus impedance matching explainedAn Isolation Transformer is characterized by:Why a Wye transformer is used to supply balanced three-phase power with a neutralWhich configuration outputs three phases and a neutral and is commonly used to supply balanced three-phase power?
More practice questions

These questions are part of the practice quiz. Start practicing

  • Which of the following is NOT listed as a factor in redundancy considerations?
  • Which component maintains a constant engine RPM by adjusting fuel delivery to the prime mover?
  • Which component was introduced to organize and connect cabling within data centers?
  • Which category cable supports 10 Gbps Ethernet?
  • Conduction is heat transfer through direct contact between particles.
  • Which statement about the role of the CRAC unit is true?
  • A higher MTBF indicates what about the time between failures?
  • Which option best describes an indirect air evaporative system (basic system)?
  • CRAC stands for which term?
  • Relief Air Fans are used to achieve what benefit?
  • Circular mils are used to express the cross-sectional area of a conductor, which primarily influences what?
  • What is the unit of resistance?
  • In electronics, a circuit is defined as:
  • Which statement best describes field wired power distribution?
  • In a Contained System CRAC, which of the following is true?
  • Direct to chip (liquid cooling) is characterized by which description?
  • What characterizes the direct air basic system?
  • Electrical control is typically implemented with which components?
  • Which device is primarily used to manage distribution of electric power and may reduce voltage for equipment?
  • In cable installation practices, amperages and wire sizes should be de-rated by what percentage?
  • What best describes a direct expansion system (basic)?
  • What does the acronym CISSP stand for?
  • NEMA stands for which organization?
  • Longer MTTR has what effect on system availability?
  • Single phase AC power is characterized by which of the following?
  • Direct digital control advantages include which feature as a defined benefit?
  • Standby power refers to which of the following?
  • Which component is responsible for controlling the voltage produced at the alternator’s output?
  • Heat of Vaporization is the energy required to change a substance from liquid to gas.
  • Which component must be used with a chiller to remove heat in data center cooling?
  • According to the breakdown, which component accounts for 30% of power system failures?
  • In an open control loop, which statement is true?
  • Which device is designed to interrupt a circuit when a ground fault is detected?
  • Heat rejection is best described as which of the following?
  • What is a Stream Canister Humidifier specifically described as?
  • A self-contained roof-top unit is typically used in data centers that are part of a what?
  • What is the dehumidifying purpose?
  • The term Power Distribution Generator refers to which type of power source?
  • Mean Time Between Failure describes what?
  • Which fiber type is used for moderate distances?
  • Which statement best describes a self-excited generator?
  • Which statement about factory configured PDU distribution is true?
  • Which device is used to warm a diesel or gasoline engine prior to starting to reduce friction?
  • Which statement defines the humidifying purpose?
  • A floor mounted precision system is described as which of the following?
  • Which interruption type lasts from 30 cycles to 2 seconds?
  • Momentary interruptions last between which durations?
  • Compared with panel boards, field wired power distribution is characterized by:
  • Which statement is true about Maintaining Dew Point versus Maintaining Relative Humidity?
  • Residual-Current Devices (RCDs) are primarily used to detect what condition?
  • Direct digital control primarily relies on which type of controllers?
  • How do ultrasonic humidifiers generate mist?
  • Which topology is also called an N+1 system and requires UPS models from the same company?
  • Which term describes harmonic waveform distortions arising at integer multiples of the fundamental frequency?
  • For precision cooling, what arrangement is considered ideal?
  • A self-contained roof-top system (basic system) is characterized by which configuration?
  • In data center terms, what is the primary function of a Power Distribution Unit (PDU)?
  • What is the ventilation purpose?
  • What is an open control loop?
  • What configuration is considered ideal for precision cooling setups?
  • What is a key limitation of overhead modular distribution?
  • Which basic system is commonly used in computer rooms and small to medium data centers?
  • Which term describes a local system with packaged equipment that serves a particular area?
  • A ceiling mounted precision system is best described as?
  • Which distribution approach is commonly chosen in small capacity installations to minimize upfront cost?
  • A power distribution Outlet strip is best described as which of the following?
  • In access control models, which trio represents the three classic forms of identification?
  • Which topology is an N+1 system and described as optimally efficient but with many single points of failure?
  • What is a circuit breaker?
  • Which statement best describes the relationship between the thermostat and the controlled variable in a closed loop?
  • Which term describes the signals that can vary continuously within a range?
  • Which term describes the primary power source in a data center's power distribution?
  • Which of the following is an example of inherence-based identification?
  • What is a primary benefit of humidifiers in a data center?
  • Which set describes the full HVAC process functions?
  • Which cabling type is generally associated with better performance?
  • VESDA stands for which term?
  • Which are valid CRAC unit modes?
  • Which disturbance is extremely rare in stable utility power systems?
  • Which attribute is associated with underfloor modular distribution?
  • What is the function of an Automatic Transfer Switch (ATS) in power distribution?
  • In a data center, a circuit breaker is designed to protect equipment from damage caused by which condition?
  • Temporary interruptions last 2 seconds to 2 minutes.
  • What is the name of the stationary coil assembly in a generator where electricity for the loads begins to be generated?
  • Which mechanism involves the energy transfer by the physical movement of a fluid?
  • Mechanical generators generate electricity by using which principle?
  • Standby generators are a combination of which components mounted together?
  • Physical security primarily involves which action?
  • The heating process is defined as which action?
  • Three-phase power consists of what?
  • Large floor mounted systems can cool approximately how much per chassis?
  • Network security is described as primarily what?
  • Which statement describes Double Conversion online topology?
  • Under which condition does UPS stored energy mode operate?
  • Circular mil is a unit used to express which property of a conductor?
  • Which fiber type is used for the longest distance transmissions?
  • Which device filters electrical spikes?
  • What is defined as the ability of a system to perform?
  • RCD is another term for Residual-Current Devices.
  • The transformer configuration used to convert from a delta connection to a wye connection to provide a neutral is:
  • The Main Electrical Service Panel is described as housing:
  • Which statement best defines the ventilation purpose?
  • Nominal voltage is defined as:
  • Infrared humidifiers employ which mechanism?
  • Latent heat is the energy required to change the state of a substance.
  • Which element is described as receiving input from sensors and responding to data?
  • Which device generates electricity by electromagnetic induction?
  • An ampere measures what?
  • Which statement best describes ground loops?
  • What does WHIP refer to in data center cabling?
  • Which term is used for a device that detects imbalance between live and neutral currents and trips?
  • Which type of circuit breaker trips due to heating from current?
  • Which term best describes the degree to which a system is operational and accessible?
  • Electromagnetic systems are described as using which energy sources to generate electrical current?
  • What term describes a local system with packaged equipment that serves a particular area?
  • What defines a chilled water system (basic)?
  • The Earth Ground Connection provides:
  • In UPS normal mode, how does the system power the load?
  • Instantaneous interruptions are defined as which duration?
  • Which term describes sudden high peak events that raise voltage and/or current levels in either a positive or negative direction?
  • What is the heating purpose in an HVAC system?
  • Which statement best describes a four-stroke engine?
  • Which design principle is highlighted as making modular scalable components advantageous?
  • Where are the refrigeration cycle components located in a basic water cooled system?
  • Cascade control loops are typically composed of how many control loops?
  • In terms of security depth, which data center location is described as offering the most in-depth protection?
  • What components are included in the physical infrastructure?
  • Which topology is relatively new and offers higher density than double conversion?
  • Panel distribution is typically chosen in which scenario?
  • Which category cable is associated with 10 Gig Ethernet in the material?
  • What is the cleaning process?
  • Which category includes a system that uses both air and water for cooling?
  • A Prime mover converts its fuel source into mechanical motion via its internal moving parts. Which term best describes this device?
  • Sustained interruptions last longer than 2 minutes.
  • The cooling process is defined as which action?
  • Generator cooling is achieved by which system?
  • Which device is used to monitor smoke at very early stages?
  • Which topology makes it possible to create a UPS system that never requires the load to be transferred to the utility power source?
  • Underfloor modular distribution is characterized by what?
  • Which statement describes the dehumidifying purpose?
  • Which term describes waveform distortion caused when direct current is added to an AC power source, potentially heating equipment?
  • Delta to WYE transformers are used to:
  • Fiber optic cables transmit data using what medium?
  • MTBF stands for which of the following?
  • What is the voltage loss percentage over distance?
  • Harmonic waveforms are a form of waveform distortion. Which term describes such distortions?
  • A volt is the unit of measurement for which electrical property?
  • Which component is identified as a critical element for the reliable operation of the starter motor?
  • Direct Air (basic system) is typically associated with data centers of what size?
  • A Server plug is best described as which of the following?
  • In data centers, what does PDU stand for?
  • Receptacles in a data center electrical system primarily serve which function?
  • In a data center power architecture, the term Power Distribution Utility refers to which power source?
  • Stranded copper cables are characterized by which features?
  • Which category includes a system that relies exclusively on water for cooling?
  • GFCI breakers provide protection against which type of electrical fault?
  • Which topology is chosen for large complex installations?
  • Which filters are typically used in a generator to ensure clean intake and fuel supply?
  • Which method transfers heat by electromagnetic waves?
  • Which type of heat is associated with a phase change and is not directly sensed by a thermometer until the phase change occurs?
  • Failure is defined as what?
  • Which category cable was historically used for 100BASE-T Ethernet?
  • How do Infrared Humidifiers operate?
  • Which device maintains a continuous supply of electrical power?
  • Which description matches a Target System CRAC?
  • Which term describes the process of verifying identity before granting access?
  • Ultrasonic humidifiers commonly require which type of water purification to supply water?
  • Which of the following is listed as a fuel option?
  • Which option describes the air movement process?
  • What is Demand Fighting in a data center cooling system?
  • What is the air movement purpose?
  • Which excitation method means the electromagnetic field is powered by energy generated within the unit itself?
  • Why is generator grounding important in power infrastructure?
  • Which component includes sensors and contact closures as examples?
  • Which component ensures all phases are equally loaded in distribution?
  • Heat of Fusion is the latent heat associated with changing a substance from solid to liquid.
  • Five 9's denotes which availability percentage?
  • What is the cleaning purpose?
  • What is the common form of Boyle's Law?
  • Enable/disable control can be implemented via which signaling method in the material?
  • What term describes air that is at 100% relative humidity?
  • Factory configured PDU distribution relies on what to improve reliability?
  • The indirect air evaporative system is common in what size data center?
  • Nominal voltage equals:
  • Fiber is generally more expensive for short distances.
  • Which topology is chosen for large, complex installations and emphasizes distributed redundancy?
  • Which process removes particles and biological contaminants from air delivered to conditioned space?
  • Which phenomenon is defined as an RMS increase in AC voltage at the power frequency for durations greater than a few seconds?
  • Which statement best describes a standby UPS?
  • What term best describes signals that can be either on or off?
  • Sag and Undervoltage refers to which description?
  • Which term describes heat energy that can be directly measured and felt?
  • Pneumatic control commonly carries which problem not usually associated with other methods?
  • A portable system (spot coolers) in precision cooling is best described as?
  • What does the governor primarily regulate in a generator system?
  • Which mechanism does a magnetic circuit breaker use to interrupt current?
  • Which statement best describes the electrical load in a data center?
  • Which device converts mechanical energy from the prime mover into alternating current (AC)?
  • What is the primary role of Precision Cooling Systems in a data center?
  • Enable/disable control turns on and off what?
  • Pneumatic control is commonly associated with which problem?
  • Which term refers to increasing moisture content in indoor air?
  • Which statement about maintaining dew point and demand fighting is true?
  • Which generator design is characterized by energy transfer without any physical contact between moving parts?
  • What describes the UPS high efficiency normal mode?
  • Which description best defines physical infrastructure?
  • A WYE transformer outputs:
  • Which option best describes a line interactive UPS?
  • What is a closed control loop?
  • The term 'main stator' refers to which part of a generator?
  • Which describes digital input/output behavior?
  • Water cooled systems (basic) are commonly found in which environments?
  • What is the dehumidifying process?
  • What term best describes signals that can vary within a range?
  • Reliability is defined as what?
  • Which statement best describes a brushless generator?
  • What term best describes a collection of plants that provide service to a widespread area?
  • Short cycling in a data center cooling scenario is described as:
  • In a control system, which component measures physical quantities and provides data to the system?
  • What characterizes a Stream Canister Humidifier?
  • What does the Automatic Transfer Switch (ATS) do in a generator setup?
  • In generator lubrication, which type of filtration system is used to filter the lubricant before it reaches moving parts such as bearings?
  • CRAC stands for which of the following?
  • Which component's primary function is to collect data and compare measurements to determine a control action?
  • Which gas law expresses that the product of pressure and volume is constant for a fixed amount of gas at constant temperature?
  • What is the described purpose of patch panels in data center cabling?
  • What is the air movement process?
  • What topology is described by a DC network topology in the material?
  • Which topology is described as an N+1 system that is optimally efficient but has many single points of failure?
  • Hertz is a unit that describes which quantity?
  • RCD is another term for which protection device?
  • What is the primary function of branch circuits?
  • Which component changes its state based on the control output?
  • Which topology adds filtration and reduces switching transient compared with standby topology?
  • Which statement best defines latent heat?
  • Which combination of MTBF and MTTR yields the highest availability?
  • Which statement describes a glycol cooled system (basic)?
  • A four-stroke engine consists of which of the following?
  • The ceiling mounted precision system is a small device suspended where?
  • What does a Computer Room Air Handler (CRAH) unit use to remove heat?
  • HVAC components are described as a sequence consisting of which four elements?
  • What is the ventilation process?
  • Which statement best describes the HVAC process scope?
  • What is a primary benefit of using humidifiers in data centers?
  • When air reaches 100% relative humidity, the air is considered in what condition?
  • MTTR stands for which of the following?
  • In data center monitoring, which detector is best for indicating incipient issues?
  • Which component is used to manage and organize the network cabling at the equipment rack?
  • ELCI stands for which device?
  • Which system contains all refrigeration cycle components in one enclosure and is common in computer rooms?
  • Which term refers to a component that converts fuel energy into mechanical motion?
  • Which term describes the signals that represent on/off states?
  • Which component controls air flow?
  • What are feeders in data center electrical distribution?
  • Which statement describes a Flooded Air Distribution System?
  • In a typical power system failure breakdown, which component accounts for 40%?
  • Three-phase power consists of how many waveforms and what is their offset?
  • The cooling purpose in an HVAC system is to?
  • A Power Distribution Unit (PDU) primarily does what?
  • Which statement describes Hybrid conversion online topology?
  • Large floor mounted systems in precision cooling are capable of cooling how much per chassis, and how should they be deployed?
  • What is the primary function of the generator voltage regulator?
  • Electromagnetic systems generate electrical current using which energy sources?
  • Which term is described as another form of waveform distortion?
  • Subpanels are described as:
  • Direct digital control can support which of the following characteristics?
  • Which of the following is NOT listed as a fuel option?
  • Normal voltage refers to:
  • Which category cable supports 1 Gbps Ethernet?
  • Five 9's denotes what measure in data center availability?
  • Which description best fits an air cooled system (basic)?
  • Which CRAC unit mode directly removes moisture from the air?
  • Immersive (liquid cooling) is defined by which statement?
  • Which description accurately describes a CRAC unit?
  • What describes the humidifying process?
  • Which distribution approach is implemented with zero footprint on the IT floor but may be limited by ceiling height?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy